Energy Science / BioLogic / Potentiostats, Premium

SP-300 Potentiostat - BioLogic


Optimize Your Research with BioLogic's SP-300 Potentiostat

The SP-300 Potentiostat from BioLogic stands at the forefront of electrochemical research technology, offering unparalleled precision, versatility, and ease of use for scientific innovation. Engineered for researchers demanding the highest level of performance, the SP-300 boasts a broad current range from 500 mA up to 10 A, inbuilt Electrochemical Impedance Spectroscopy (EIS), and a slew of advanced features such as a 7 MHz maximum frequency, floating mode capability, and analog filtering. This modular system, capable of integrating high current/high voltage or an additional potentiostat/EIS board, facilitates complex experiments including RRDE and multi-user scenarios. Tying this power together is the acclaimed EC-Lab software, renowned for its intuitive operation and deep analytical capabilities, making it the choice instrument for those seeking to push the boundaries of electrochemical research.

Technical information

General
Slots availableUp to 2
Electrodes connections2, 3, 4, 5
Compliance± 12 V
Acquisition time1 µs with ARG option, 20 µs with EC-Lab developer package, 200 µs with EC-Lab.
Live processed data : 200 µs, independent of sampling rate (Q charge, Q discharge, Energy, Power…)
SoftwareEC-Lab, EC-Lab developper package
Add-ons compatibilityYes
Dimension (W x D x H)205 x 410 x 225 mm
Weight7.5 kg
Power requirement350 W
InterfacesEthernet (Direct, LAN, Wifi), USB 2.0
Control
Measurement
Voltage
RangesCustomizable ranges. Adjustable from ± 10 V down to ± 30 mV.
Up to [0; 48] V with HCV-3048
± 10 V customizable
Accuracy< ± 1 mV ± 0.03 % of setting< ± 1 mV ± 0.03 % of reading
ResolutionFrom 1 µV (± 60 mV range) to 333 µV (± 10 V range)76 µV (7.6 µV for ± 250 mV, 0.76 µV for ± 25 mV, ZRA only)
Current
Ranges± 1 A to 10 nA (9 ranges),
up to 120 A with four HCV-3048
down to ± 1 pA using Ultra Low Current option
240 % of range value, except for the 1 A range (50 % of range)
Accuracy< ± 0.1 % of range ± 0.03 % of setting< ± 0.1 % of range ± 0.03 % of reading
Resolution
0.004 % of the range : 760 fA (standard), 76 aA (Ultra Low Current option
EIS
EIS capability
7 MHz to 10 µHz
Frequency resolution
< 10 ppm of the setting
EIS quality indicators
Yes
Advanced
Floating optionsFloating, WE to ground, CE to ground
Permeation (WE to ground)Yes
Multi-electrode (CE to ground)Yes
FiltersHardware / Software
Input/Output2x analog inputs
1x analog output
3x TTL (trigger input/output, and safety)
2x monitor outputs (current and voltage)
Stability control mode9 bandwidths
CalibrationOne calibration board included, more than 100 verified points.